Thermo Scientific Cellomics High-Content
Screening Products
arrowHome arrow Products arrow HCS Reagent Kits arrow Phospho-4E-BP1 Detection Kit Part of Thermo Fisher Scientific  


 
Search

Navigation
Home
Products
HCS Reagent Kits
HCS Library
Training
Promotions
Careers

New Products

Special Offers
Complimentary HCS Technical Posters Click to download posters from
CHI-HCA 2007
SBS 2007

Submit a publication to HCS Library on Cellomics.com and win a $25 Amazon gift card


 

 
Phospho-4E-BP1 Detection Kit Print E-mail
Cellomics HCS Reagent Kit for detection of phosphorylated 4E-binding protein (4E-BP1), a downstream effector of mTOR induced translational control.
Normal phospho-4E-BP1 expression before inhibitory treatment
Treat HeLa cells with Ly294002
Inhibited phospho-4E-BP1 expression
Analyze cell image data
Dose response of phospho-4E-BP1 to Ly294002

Normal
phospho-4E-BP1
expression

treat cells
Inhibited
phospho-4E-BP1
expression
analyze
conclude
Description

The Cellomics Phospho-4E-BP1 Detection Kit enables quantitation of phosphorylated 4E-BP1 protein (phospho-4E-BP1) (Figure 1). Phospho-4E-BP1 is measured directly using a fixed end-point assay based on immunofluorescence detection in cells grown on standard high-density microplates. This kit contains an anti-phospho-4E-BP1 primary antibody (rabbit monoclonal), a goat anti-rabbit secondary antibody conjugated to DyLight 549 Fluorophore and various other reagents and buffers required for immunofluorescence staining for high-content screening (HCS) assays.

Downstream effectors of mTOR-induced translational control include ribosomal protein S6 kinase (S6K) and the eukaryotic initiation factor 4E (eIF4E)-binding protein (4E-BP1). The 4E-BP1 (eIF4E-binding protein 1, also called PHAS-I) is a small heat- and acid-stable phosphoprotein whose phosphorylation is enhanced by growth factors, serum stimulation and insulin in a PI3 kinase-dependent manner. 4E-BP1 undergoes phosphorylation at several sites leading to its release from eIF4E and allowing eIF4E to bind eIF4G and form initiation complexes that facilitate upregulation of protein synthesis (Figure 2).

This kit was optimized using the Thermo Scientific ArrayScan HCS Reader and the Compartmental Analysis BioApplication Software Module but can be used with other Cellomics BioApplications. Thus, automated plate-handling, focusing, cell image acquisition and data analysis are combined in one HCS system to assay for compounds that regulate phospho-4E-BP1 induction. In addition to HCS instruments, cells stained using reagents in this kit can be viewed and analyzed by fluorescence and confocal microscopes.


Stained phospho-4E-BP1 in HeLa cells treated with media (non-treated) or mTOR inhibitor Ly294002
     Downstream effectors of mTOR include 4E-BP1

Figure 1. Staining of phospho-4E-BP1 in HeLa cells treated with media (non-treated) or with Ly294002 (100 µM) for 16 hours. Cells were fixed and stained according to the kit protocol with Hoechst 33342 dye for nuclei (blue) and Phospho-4E-BP1 primary antibody plus DyLight 549 Goat Anti-Rabbit Secondary Antibody (orange). Stained cells then were imaged using the ArrayScan VTI HCS Reader. Treatment with Ly294002 inhibits expression of phospho-4E-BP1.

 

Figure 2. Downstream effectors of mTOR induced translational control include ribosomal protein S6 kinase (S6K) and the eukaryotic initiation factor 4E (eIF4E)-binding protein (4E-BP1). Activation of S6K and its substrate S6 phosphorylation is blocked by mTOR inhibitor rapamycin. Phosphorylation of 4E-BP1 is inhibited by the PI3 kinase inhibitor Ly294002.

 

Dose response curves of phospho-4E-BP1 in  A549, HepG2 and HeLa cells

Figure 3. Dose response curves for phospho-S6 in A549 and HeLa cells. The average intensities of phospho-S6 in the cytoplasm are plotted in response to rapamycin or Ly294002 concentration in cells treated for 16 hours. EC50 values for both inhibitors and cell types are listed.

Related Poster Presentations
Cellomics HCS Reagent Kit academic posterKay Opperman, Krishna Vattem, and Richik N. Ghosh (2008) High-Content Analysis of Multiple Key Proteins in the AKT Signaling Pathway.
Kit Contents
Component
8405301
8405302
Phospho-4E-BP1 Primary Antibody
22 µl
110 µl
DyLight 549 Conjugated
Goat Anti-Rabbit IgG
14 µl
72 µl
Hoechst Dye
30 µl
30 µl
Wash Buffer (10X Dulbecco's PBS)
100 ml
100 ml
Wash Buffer II (10X Dulbecco's PBS with
Tween®-20)
100 ml
100 ml

Permeabilization Buffer (10X D-PBS with 1% Triton® X-100)

100 ml
100 ml
Blocking Buffer (10X)
85 ml
85 ml
Thin Plate Seal Assembly
7/pack
7/pack
Ordering Information

Screening size kits and components (bulk and custom) available with special pricing. Please call.

To order Cellomics HCS Reagent Kits, please call 800-874-3723 in the U.S.
or contact your local distributor of Thermo Scientific Products.

Choose "Order Online" in table to see pricing and order online (U.S. only).

BuyProduct #DescriptionPkg. Size
Order Online8405301Phospho-4E-BP1 Detection Kit1 x 96
Order Online8405302Phospho-4E-BP1 Detection Kit5 x 96

See all Cellomics HCS Reagent Kits

 

 

Last Updated ( Tuesday, 29 January 2008 )
 
Upcoming Events
May 17, 2008
ISAC XXIV International Congress Please join us at the International Society for Analytical Cytology's International Congress:  Cytometry in the Age of Systems Biology at the Bud ...


Contact Us

Thermo Fisher Scientific
Cellular Imaging:
1.800.432.4091 (Toll free)
412.770.2500
Fax: 412.770.2450
E-mail


Sales Information -
Thermo Fisher Scientific
Cellular Imaging, Europe
:
+44 (0)118.988.0262
Fax: +44 (0)118.988.0362

General inquires:
1.800.432.4091
E-mail
Product Service and
Technical Support:
1-800-432-4091 - Ext. -2525
E-mail

Thermo Fisher Scientific Japan
Cellular Imaging
C-2F, 3-9 Moriya-cho
Kanagawa-ku, Yokohama
221-0022, Japan
Phone: +81-45-453-9220
Fax: +81-45-453-9222
www.cellomics.jp

 


ClubHCS

ClubHCS is a resource to help you with your HCS experience as well as the opportunity to interact with the worldwide community of HCS users.

If you currently use an ArrayScan® or KineticScan® HCS Reader or a cellWoRx™ High Content Cell Analysis System, click here to Register


 
top

Thermo Fisher Scientific Inc.